EX-5150-MOS
Sensor/Transmitter
For PPM or %LEL
Manual
Vue de la page 0
1 2 3 4 5 6 ... 18 19

Résumé du contenu

Page 1 - For PPM or %LEL

ENMET Corporation PO Box 979 Ann Arbor, MI 48106-0979 Manual Part Number 80003-097 MCN-414, 03/25/09 EX-5150-MOS Sensor/

Page 2 - List of Figures and Tables

EX-5150-MOS ENMET Corporation 8 5.0 Maintenance of the EX-5150-MOS CAUTION: Do not open the EX-5150-MOS S/T in a classified area. CAUTION: Do Not

Page 3 - 1.0 Introduction

EX-5150-MOS ENMET Corporation 9 5.2 Calibration of the EX-5150-MOS Calibration is the process of setting the instrument up to read accurately whe

Page 4 - Menu Select

EX-5150-MOS ENMET Corporation 10 Table 3: Standard and Non-Standard Calibration Gas Gas Range Alarm 1* Alarm 2* Alarm 3* Sensor Part Number

Page 5

EX-5150-MOS ENMET Corporation 11 5.2.1 Zero Adjust A ZERO function should be performed only when the EX-5150-MOS sensor/transmitter is exposed to

Page 6

EX-5150-MOS ENMET Corporation 12 Normal Display Mode OR Zero Cal OK If the Zero signal is within Preset Specs the EX-5150-MOS will disp

Page 7

EX-5150-MOS ENMET Corporation 13 5.3 Heater Voltage Settings Heater Voltages are necessary for MOS sensors. They are preset at the factory and s

Page 8 - S/W X.X

EX-5150-MOS ENMET Corporation 14 7.0 WARRANTY ENMET warrants new instruments to be free from defects in workmanship and material under normal use

Page 9 - 4.1.3 Purge

EX-5150-MOS ENMET Corporation 15 Addendum: Ammonia Calibration Calibration Procedure for EX-5150-MOSAmmonia The EX-5150-MOSAmmonia sensor require

Page 10

PO Box 979 680 Fairfield Court Ann Arbor, Michigan 48106-0979 734.761.1270 Fax 734.761.3220 Returning an Instrument for Repair ENMET instru

Page 11 - Humidifier Top View

Repair Return Form Mailing Address: ENMET Corporation PO Box 979 Ann Arbor, Michigan 48106 Phone Number: 734.761.1270 FAX Number: 734.761.322

Page 12 - Calibration Gas

Table of Contents 1.0 INTRODUCTION ...

Page 13 - Table 2: Calibration Time

EX-5150-MOS ENMET Corporation 1 1.0 Introduction The ENMET EX-5150-MOS sensor/transmitters (S/T) is a 3-wire 24 VDC 4-20mA S/T for the detection

Page 14

EX-5150-MOS ENMET Corporation 2 2.0 Features of the EX-5150-MOS See Figure 1 for location of features: Feature Description Display LCD: Indicate

Page 15 - 6.0 Replacement Part Numbers

EX-5150-MOS ENMET Corporation 3 3.0 Installation of the EX-5150-MOS CAUTION: Area must be declassified during installation. The ENMET EX-5150-MOS

Page 16 - 7.0 WARRANTY

EX-5150-MOS ENMET Corporation 4 3.2 Wiring the EX-5150-MOS to a Control Unit CAUTION: Area must be declassified during installation. Run conduit

Page 17

EX-5150-MOS ENMET Corporation 5 Figure 3: Terminal Positions EX-5150-MOS Sensor/Transmitter When wiring is complete re-assemble the EX-51

Page 18

EX-5150-MOS ENMET Corporation 6 4.0 Operation of the EX-5150-MOS It is best to have the EX-5150-MOS transmitters powered up and operational for 2

Page 19 - Repair Return Form

EX-5150-MOS ENMET Corporation 7 4.1.3 Purge Purging is a function that temporarily increases the sensor heater voltage to clean off contaminants.