Enmet EX-5000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Enmet EX-5000. ENMET EX-5000 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
ENMETENMET Corporation
PO Box 979
Ann Arbor, MI 48106-0979
80003-029
MCN-182, 02/11/98
MCN-204, 02/29/00
MCN-230, 02/29/00
MCN-234, 04/25/00
MCN-240, 10/30/00
MCN-247, 11/21/00
MCN-253, 04/05/01
MCN-265, 12/13/01
MCN-290, 11/20/02
Catalytic & MOS
Sensor/Transmitter Installation
Manual
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Catalytic & MOS

ENMETENMET CorporationPO Box 979Ann Arbor, MI 48106-097980003-029MCN-182, 02/11/98MCN-204, 02/29/00MCN-230, 02/29/00MCN-234, 04/25/00MCN-240, 10/30/00

Page 2 - List of Illustrations

ENMET Corporation MOS S/T83.2 Initial CalibrationThe S/T has been precalibrated at the factory before shipment, and initial field calibration should r

Page 3 - ENMET Corporation

Catalytic & MOS S/T ENMET Corporation94.0 WARRANTY4.0 WARRANTYENMET warrants new instruments to be free from defects in workmanship and material u

Page 4

ENMET Corporation Catalytic &MOS S/T10Addendum: Ammonia CalibrationAddendum: Ammonia CalibrationCalibration Procedure for EX-5000 MOS AmmoniaThe E

Page 5 - 2.1 Installation

Table of Contents1.0 INTRODUCTION...

Page 6 - SENSOR WIRING

Catalytic & MOS S/T ENMET Corporation11.0 Introduction1.0 IntroductionThe ENMET catalytic and MOS sensor/transmitters (S/T) are, three or four wir

Page 7

ENMET Corporation Catalytic S/T21.2 Features of Sensor / Transmitter1.2.1 Magnetic Switches and PotentiometersMagnetic switches control the span and p

Page 8 - 3.1 Installation

Catalytic S/T ENMET Corporation32.0 Catalytic Combustible Gas Sensor/Transmitter Installation2.0 Catalytic Combustible Gas Sensor/Transmitter Installa

Page 9 - 812 / 813 / 814 SENSOR WIRING

ENMET Corporation Catalytic S/T42.1.2 WiringRun conduit and 16 AWG wires to the enclosure from the power supply and controller. Since combustible gas

Page 10

Catalytic S/T ENMET Corporation5Figure 3: Catalytic Combustible Gas Sensor/Transmitter1. Apply the calibration gas associated with the S/T to the sen

Page 11 - 4.0 WARRANTY4.0 WARRANTY

ENMET Corporation MOS S/T63.0 MOS 3.0 MOS Combustible and Toxic Vapor Sensor/Transmitter InstallationCombustible and Toxic Vapor Sensor/Transmitter In

Page 12

MOS S/T ENMET Corporation73.1.2 WiringRun conduit and 16 AWG wires to the enclosure from the power supply and controller. Since combustible gas may b

Commentaires sur ces manuels

Pas de commentaire